Product Overview
The 02/05 Series Compact Electric Actuators are designed to deliver high torque output in a compact and lightweight structure. They offer reliable performance, precise positioning, and long service life, making them suitable for a wide range of industrial automation and valve control applications.
The 02 Series features a durable engineering plastic housing, while the 05 Series is constructed with a die-cast zinc alloy housing. Both models incorporate an all-metal gear transmission system and high-precision bearings to ensure stable operation and durability under demanding working conditions.
A user-friendly three-button control panel allows convenient operation and parameter configuration. The high-resolution OLED display provides clear information, including actuator status, settings, and fault notifications. Its low power consumption and long service life make it suitable for continuous industrial use.
The actuator is powered by a brushless DC motor, combining compact dimensions with high torque output, low power consumption, and long service life. Built-in torque protection helps prevent damage caused by excessive loads or valve jamming.
A high-durability position sensor provides accurate position feedback and is designed for more than one million operating cycles. The actuator also features wear-resistant silicone sealing components, a stainless steel output shaft, and an internal protection design against moisture and corrosion.
Multiple power supply options and control interfaces are available, including analog signals, digital switching signals, RS-485 communication, and wireless control solutions.
Key Features
| Feature | Description |
|---|---|
| Compact Design | Small overall dimensions with a standard 8 mm internal octagonal output connection for versatile installation. |
| OLED Display | High-resolution display with an intuitive interface for configuration, monitoring, and diagnostics. |
| Low Power Consumption | Brushless DC motor delivering high torque, high efficiency, and extended service life. |
| Easy Installation | Standard wiring terminals with optional customized cable assemblies. |
| Electrical Isolation | 2000 V isolation between input signals, output signals, and the power supply. |
| Multiple Power Options | AC 24 V, 110 V, 220 V and DC 12 V, 24 V options. |
| Flexible Control Signals | Supports switching signals, analog signals, dry contacts, bus communication, and wireless networking. |
| EMC Performance | Designed with protection against electromagnetic interference, electrostatic discharge, lightning surges, and overheating. |
| Overload Protection | Built-in torque protection, fault diagnostics, and alarm output. |
| Additional Functions | Electronic valve position calibration, position-reached dry contact output, and optional wireless control and networking. |
Technical Specifications
Electrical Performance
| Parameter | Specification |
|---|---|
| Power Supply | DC 12 V / 24 V; AC 24 V / 110 V / 220 V / 380 V |
| Standby Power Consumption | ≤ 5 W |
| Rated Load Power Consumption | ≤ 15 W (DC 24 V); ≤ 20 W (AC 220 V) |
| Stall Power Consumption | ≤ 30 W (DC 24 V); ≤ 40 W (AC 220 V) |
| Maximum Stall Duration | ≤ 3 seconds |
| Input Control Signal | 4–20 mA |
| Input Impedance | ≤ 120 Ω |
| Input Accuracy Error | ≤ 0.1% |
| Input Resolution | 0.1% |
| Input Repeatability Error | ≤ 0.1% |
| Input Temperature Drift | ≤ 0.1% / 20°C |
| Position Feedback Signal | 4–20 mA |
| Output Load Resistance | ≤ 500 Ω |
| Output Accuracy Error | ≤ 0.1% |
| Output Resolution | 0.1% |
| Output Repeatability Error | ≤ 0.1% |
| Output Temperature Drift | ≤ 0.1% / 15°C |
| Valve Position Potentiometer | 10 kΩ |
| Potentiometer Input Resistance | ≥ 1 kΩ |
| Potentiometer Input Accuracy Error | ≤ 0.1% |
| Potentiometer Input Resolution | 0.1% |
| Potentiometer Repeatability Error | ≤ 0.1% |
| Potentiometer Temperature Drift | ≤ 0.1% / 15°C |
| Maximum System Error | Positioning Accuracy + 0.2% |
Environmental & Mechanical Specifications
| Parameter | Specification |
|---|---|
| Relative Humidity | ≤ 90% RH |
| Shock Resistance | 2 g |
| Operating Temperature | -25°C to +55°C |
| Extreme Temperature Range | -45°C to +75°C |
| Service Life | ≥ 3 years or 20,000 operating hours (at 0–35°C) |
| 02 Series Weight | 0.2 kg |
| 05 Series Weight | 1.6 kg |
| 02 Series Dimensions | 69 × 61 × 58 mm (L × W × H) |
| 05 Series Dimensions | 110 × 90 × 82 mm (L × W × H) |
Weight excludes accessories. Dimensions exclude mounting brackets.
Accessories & Options
| Category | Description |
|---|---|
| Standard Accessories | User manual, certificate of conformity, and other specified accessories |
| Optional Accessories | Wireless remote controller, RS-485 to USB converter, LCD signal source |
| Packaging & Transportation | According to manufacturer specifications |
Available Control Options
The actuators support various control methods to meet different automation requirements:
-
Analog Control: 4–20 mA control and position feedback.
-
Digital Control: Switching signals and dry contact interfaces.
-
Communication: RS-485 communication for integration with industrial automation systems.
-
Wireless Control: Optional remote operation and wireless networking.
-
Position Calibration: Electronic valve position calibration and position-reached feedback.
-
Fault Monitoring: Overload detection, fault diagnostics, and alarm output.
Typical Applications
Suitable for a wide range of automated valve control systems, including:
-
HVAC and building automation
-
Industrial process control
-
Water treatment systems
-
Automated valve positioning
-
Fluid control and distribution systems
-
Industrial equipment and automation systems