1. Product Overview
This large-diameter PTFE lined sampling valve is designed for online sampling on main pipelines of large-diameter pipelines and reaction kettles. The entire flow channel of the valve body is lined with PTFE (Polytetrafluoroethylene). It adopts straight-through large-bore flow passages at the top and bottom, matched with a side integrated closed sampling unit. With a stainless steel base plus PTFE lining structure, it can withstand various strong acids, strong alkalis and highly corrosive media. It supports vertical pipe and horizontal pipe installation, solving the pain points of ordinary small-bore sampling valves such as easy blockage and poor corrosion resistance for large-diameter process pipelines. It is widely used in fluorine chemical industry, new energy materials, pickling, pesticides, fine chemical industry and other highly corrosive working conditions.
2. Structural Composition
The large-diameter straight-through valve body adopts a wide-bore flange structure, with sufficient flow diameter and large flow space. Slurry, high-viscosity and easy-crystallization materials are not easy to remain, ensuring smooth pipeline fluid. The whole PTFE lined flow channel: all medium contact areas are fully lined with PTFE. The metal shell does not contact corrosive materials directly, which effectively resists corrosion from hydrofluoric acid, strong acid, strong alkali, strong oxidizing media. Side closed sampling structure: a sampling branch is installed on the side, the sampling passage is also lined with anti-corrosion material. It can connect sampling bottles to realize closed sampling without volatilization. The sampling branch is independent, it will not affect the normal continuous production of the main pipeline. Standard flange connection at top and bottom: the upper and lower standard flange ports can be directly connected to DN50 and above large-diameter process pipelines and inlet/outlet ports of reaction kettles. It has great installation compatibility. The modular structure is easy to disassemble, maintain and replace sealing parts.
3. Core Advantages
Large-diameter design, not easy to block: Compared with conventional small-bore sampling valves, it has a larger inner cavity, suitable for suspended slurry, high-viscosity and easy-crystallization materials, avoiding pipeline blockage and sedimentation, and guaranteeing the representativeness of samples. Full PTFE anti-corrosion lining: The medium contact area is lined with PTFE, applicable to most strong acid and strong alkali chemical working conditions, solving the limitation that 316L stainless steel cannot adapt to hydrofluoric acid and concentrated alkali. Independent branch closed sampling: The sampling branch is separated from the main flow channel. Sampling operation will not interrupt production. The whole process is closed to prevent leakage of toxic and volatile corrosive media, protect operator safety and meet environmental protection and production safety specifications. Flexible installation modes: Supports horizontal and vertical pipeline installation. It can be used for sampling from large reaction kettles as well as online sampling on large-diameter conveying pipelines. Easy cleaning and residual removal: The inner cavity of the valve has few dead zones. After sampling, clean water or inert gas can be introduced to purge residual media to prevent material crystallization and solidification, and avoid cross-contamination between batches of samples.
4. Application Scope
Working Conditions
Online sampling for large-diameter process pipelines and inlet/outlet pipelines of large reaction kettles; sampling under normal and positive pressure corrosive medium conditions; process scenarios with particulate solid content, slurry, high viscosity, easy crystallization and volatile corrosive media.
Applicable Industries
Fluorine chemical industry, new energy electrolyte, fine chemical industry, pesticide intermediates, electroplating pickling, sewage treatment, inorganic chemical production industries.
Applicable Media
Hydrofluoric acid, hydrochloric acid, sulfuric acid, various strong alkali solutions, corrosive salt solutions, acidic materials, strong oxidizing liquid materials.
5. Basic Operation Procedure
- Connect the valve flange to the process pipeline, complete sealing assembly and connect the sampling container.
- Slowly open the branch valve, and the stable medium from the main pipeline enters the sampling unit.
- After collecting sufficient samples, close the sampling passage.
- Connect the purge medium to flush the residual materials inside the sampling branch and valve cavity.
- Release pressure and take out the sampling container, sampling finished.
6. Optional Custom Parameters
Valve body material: 304 / 316L stainless steel; Lining material: PTFE (upgradable to PFA) Standard sizes: DN50, DN65, DN80, DN100, non-standard customization available Flange standard: Domestic HG, GB; American Standard ANSI B16.5 Sealing configuration: PTFE, FFKM perfluoroelastomer seals Optional extensions: Pressure balance interface, pneumatic actuator, visual sampling assembly















