Product Overview
The foot valve is generally installed at the bottom of a water pump’s suction pipe to prevent liquid from flowing back into the water source, allowing flow in only one direction. The valve cover features multiple water inlets and reinforcing ribs to help prevent clogging. It is mainly used in water pumping systems to control water flow and support the suction piping. Connection methods include flange and threaded connections. The valve mainly consists of a valve body, valve core, valve disc, and filter screen.
Structure and Working Principle
The foot valve consists of a valve body, valve disc, valve cover, bushing, sealing ring, and other components.
Water enters the valve body through the valve cover. Under fluid pressure, the valve disc opens to allow water to flow through. When the pump stops, pressure in the outlet pipe causes the valve disc to close quickly, preventing liquid from flowing back into the water source.
This ensures smooth water pumping while reducing energy loss.
Technical Specifications
Suitable Media: Water, oil, and non-corrosive liquids
Operating Temperature: ≤80°C
Main Sealing Material: Nitrile Butadiene Rubber (NBR)
Manufacturing Standard: Q/12 NJ3583-2001
Testing Standard: GB/T 13927-1992