The ZMQ straight-through diaphragm pneumatic shut-off valve consists of two main components: an actuator and a linear-stroke control valve mechanism, which are connected by a mounting bracket.
The ZMQ straight-through diaphragm pneumatic shut-off valve can be installed in straight pipelines and equipped with an electro-pneumatic valve positioner to achieve fine adjustment of the control valve.
It is available in three types:
-
Straight-through single-seat shut-off valve (ZMQP)
-
Straight-through sleeve-type shut-off valve (ZMQM)
-
Two-position three-way shut-off valve (ZMQN)
The pneumatic actuator can be either piston-operated or diaphragm-operated, with two operating modes: single-acting (spring return) and double-acting (double air supply).
The valve body is available in three configurations: single-seat, sleeve-type, and double-seat (two-position three-way). Two sealing options are available: packing seal and bellows seal.
The ZMQ pneumatic shut-off valve can be equipped with a solenoid valve according to customer requirements, including standard or explosion-proof versions.
The available nominal pressure ratings are PN10, PN16, PN40, and PN46. The nominal diameter range is DN20–DN200 mm.
The applicable fluid temperature range is -60°C to 450°C. Leakage classes are Class IV or Class VI. Flow characteristics include quick-opening and equal-percentage.
Product Features
The ZMQ straight-through diaphragm pneumatic shut-off valve adopts a top-guided structure and is equipped with a multi-spring actuator.
Its main advantages include:
-
Compact structure
-
Lightweight design
-
Sensitive and responsive operation
-
Smooth fluid passage with low flow resistance
-
Low pressure loss
-
Large flow capacity
-
Easy disassembly and maintenance
The ZMQ pneumatic shut-off valve receives signals from regulating instruments and performs shut-off, opening, or flow switching operations. It can automatically control process parameters such as differential pressure, flow rate, and liquid level.
It is widely used in automatic process control and remote control systems in petroleum, chemical, metallurgical, electric power, light industry, textile, and other industrial sectors.
Main Technical Parameters
| Parameter | Specification |
|---|---|
| Nominal diameter DN (mm) | 20, 25, 32, 40, 50, 65, 80, 100 |
| Rated flow coefficient Kv | 7, 11, 20, 30, 48, 75, 120, 190 |
| Rated stroke (mm) | 8, 12, 20, 25 |
| Cylinder diameter (mm) | 75, 100, 150 |
| Working temperature (°C) | -20 to 200; -40 to 450 |
| Nominal pressure PN (MPa) | 1.6, 4.0, 6.4 |
| Signal pressure (kPa) | 0 or 400–600 |
Allowable Leakage
| Sealing Type | Leakage Specification |
|---|---|
| Hard seal – single-seat and three-way valves | 1.2 × 10⁻⁷ × Rated valve capacity |
| Hard seal – sleeve type | 5 × 10⁻⁶ × Rated valve capacity |
| Soft seal | Class VI |
Allowable Differential Pressure
The following values correspond to nominal diameters DN20, DN25, DN32, DN40, DN50, DN65, DN80, and DN100, respectively.
| Valve Type | Operating Mode | DN20 | DN25 | DN32 | DN40 | DN50 | DN65 | DN80 | DN100 |
|---|---|---|---|---|---|---|---|---|---|
| ZMQP | Single-acting | 1.16 | 0.66 | 0.38 | 0.60 | 0.39 | 0.47 | 0.31 | 0.20 |
| ZMQP | Double-acting | 6.4 | 5.0 | 2.8 | 3.3 | 2.13 | 2.71 | 1.75 | 1.11 |
| ZMQM | Single-acting | Nominal pressure | |||||||
| ZMQM | Double-acting | — | — | — | — | — | — | — | — |
| ZMQN | Single-acting | 0.89 | 0.57 | 0.35 | 0.56 | 0.36 | 0.45 | 0.30 | 0.20 |
| ZMQN | Double-acting | 5.2 | 3.22 | 2.03 | 2.27 | 1.46 | 2.00 | 1.32 | 0.85 |
Note: The ZMQM double-acting values are not provided in the original table.
Notes
-
The performance and technical specifications of this product comply with GB/T 4213-92.
-
If the allowable differential pressure shown in the table exceeds the nominal pressure, the nominal pressure shall apply. If it is less than or equal to the nominal pressure, the listed value remains unchanged.
-
The allowable differential pressure values are based on standard operating springs. Different cylinder configurations can be selected to increase the allowable differential pressure.
Applications of Pneumatic Shut-Off Valves
The ZMQ straight-through diaphragm pneumatic shut-off valve is an actuator used in automated control systems. It consists of a straight-through valve body, a diaphragm actuator, and a solenoid valve.
The pneumatic shut-off valve receives signals from regulating instruments to control the shut-off, connection, or switching of fluids in process pipelines.
For piston-operated shut-off valves, the air supply must consist of filtered compressed air.
The medium flowing through the valve body must be a liquid or gas free from impurities and solid particles.
This type of valve is suitable for applications requiring remote operation, rapid opening and closing, and quick shut-off in various pipeline systems.