pneumatic actuator on off valve actuator sizing

Common Faults And Troubleshooting Methods:
  • Whether the manual device is jammed, whether the air circuit is blocked.Solution: Repair the manual device, clear the air circuit.
  • Whether the actuator is leaking, whether the air pressure is too low, whether the valve stem is deformed.Solution: Repair the actuator, increase air pressure, replace the valve stem.
  • Whether the valve parts are damaged.Solution: Replace the valve parts.
  • The manual device and the valve stem are not in position.Solution: Reset the manual device and valve position.
  • Insufficient air supply pressure.Solution: Increase the supply pressure.
  • The thrust of the pneumatic actuator is too small.Solution: Replace with a larger pneumatic actuator.
  • The valve positioner and the valve stem are not in position.Solution: Adjust the positioner and valve stem.
  • The valve closing pressure is too low or normally closed.Solution: Adjust the pressure, adjust the spring force.
  • The air pipe joint is leaking or the air supply is insufficient or the air flow.Solution: Tighten the joint.
  • The power supply is abnormal, such as the power supply circuit.Solution: Repair the power circuit.
  • The indication is incorrect.Solution: Adjust the positioner indication correctly.
  • Damaged microswitch.Solution: Replace the microswitch.

Related Post

Wind-Solar Hybrid System Introduction
Reduce Water Waste by Installing Intelligent Electric Butterfly Valves or Electric Gate Valves
Reduce Water Waste by Installing Intelligent Electric Butterfly Valves or Electric Gate Valves
pneumatic actuatoron off valve actuator sizing
Butterfly Valves, Sluice Gates and Penstock Gates for Kadda Water Treatment Plant in Bangladesh
Pneumatic ball valve Raw Sour GasNACE MR0175 / ISO 15156 standards and shall be suitable for Sour Gas service conditions.

Related Cases

Related Products

Product center

About Us

Scroll to Top