pneumatic actuator on off valve actuator sizing

Common Faults And Troubleshooting Methods:
  • Whether the manual device is jammed, whether the air circuit is blocked.Solution: Repair the manual device, clear the air circuit.
  • Whether the actuator is leaking, whether the air pressure is too low, whether the valve stem is deformed.Solution: Repair the actuator, increase air pressure, replace the valve stem.
  • Whether the valve parts are damaged.Solution: Replace the valve parts.
  • The manual device and the valve stem are not in position.Solution: Reset the manual device and valve position.
  • Insufficient air supply pressure.Solution: Increase the supply pressure.
  • The thrust of the pneumatic actuator is too small.Solution: Replace with a larger pneumatic actuator.
  • The valve positioner and the valve stem are not in position.Solution: Adjust the positioner and valve stem.
  • The valve closing pressure is too low or normally closed.Solution: Adjust the pressure, adjust the spring force.
  • The air pipe joint is leaking or the air supply is insufficient or the air flow.Solution: Tighten the joint.
  • The power supply is abnormal, such as the power supply circuit.Solution: Repair the power circuit.
  • The indication is incorrect.Solution: Adjust the positioner indication correctly.
  • Damaged microswitch.Solution: Replace the microswitch.

Related Post

What is a FRL Unit
How to Choose the Right IP Rating for Valve Actuator Accessories
Understanding Pneumatic Actuated Ball Valves
The Ultimate Guide to Angle Globe Valves
The Purpose of Bypass Valve
Balance Valves Explained: Function, Benefits, and Uses
Top-Entry Discharge Valves vs Inclined Stem Ball Valves: Selection Guide
Blowdown Valves Guide: How It Works and Where to Use It

Related Cases

Related Products

Product center

About Us

Scroll to Top